TwinEdge OS
- BACnet/IP, Modbus, OPC UA, MQTT
- ONVIF / RTSP cameras, local clips
- Durable log if the WAN drops
TwinEdge OS at the building — including cameras. Historian and cloud for live asset intelligence.
TwinEdge OS sits at the building and reads AHUs, chillers, and meters over BACnet, Modbus, or OPC UA — and ONVIF or RTSP cameras on the same box. Local history and clips keep running if the WAN drops. Facility OS uses that record in the historian and the cloud. A person still approves.
TwinEdge OS sits beside the BMS. It reads named AHUs, chillers, and meters, and ONVIF or RTSP cameras on the same box. Local history and clips stay if the WAN drops, then forward to the historian and the cloud.
A setpoint change or work draft waits in a queue. Safety envelopes and kill switches stay on.
TwinEdge OS speaks BACnet/IP, Modbus, OPC UA, MQTT, and ONVIF/RTSP cameras to named facility assets.
A durable log, local history, and camera clips stay on the box. Then the historian and cloud get the same asset.
A person approves. The job and the proof come back to the same building.
See the room and the AHU on one record.
Draft work from a finding, not a clipboard.
Energy, inspection, and closeout stay on the building.
Select a screen to explore the workflow. Open it for a closer look.
Put the AHU, chiller, and the room it serves on the same map as alarms and work.
Native C workers for BACnet/IP, Modbus, OPC UA, MQTT, Sparkplug, and SNMP.
Fault findings, rooms, IEQ, inspections, meters, bills, and ENERGY STAR on the same building record.
A person still approves.
The BMS knows the point. The CMMS knows the job. The bill knows the cost. Facility OS keeps those on one building so the operator, the crew, and finance stop arguing from different screens.
TwinEdge OS is the edge server. Facility OS is the operating layer that uses its record. Building Twin, Workplace, and Energy are gated modules. It is not a plant OS and it is not a BMS replacement.
The value is linking the BMS, the room, the job, and the bill — then carrying the evidence through repair and reporting.
Keep source context available as the workflow moves between teams and applications.
TwinEdge Facility OS
No. TwinEdge OS reads your BMS over BACnet/IP, Modbus, OPC UA, or MQTT, and cameras over ONVIF or RTSP. Those systems stay. Facility OS is the TwinEdge building layer that uses the record.
Native workers on the edge server ingest BACnet/IP (Who-Is, COV, BBMD), Modbus TCP/RTU, OPC UA, MQTT, Sparkplug B, and SNMP. Facility library types name the AHU, chiller, VAV, boiler, meter, and generator. A saved point map is required. Commissioning still validates the live panel.
Site Vision on TwinEdge OS takes local ONVIF Profile S cameras, direct RTSP streams, or a local VMS/NVR. Discovery, live view, clips, and privacy masks run on the box. Credentials are secret references, not pasted passwords or stream URLs. Cloud doorbell cameras such as Ring are lab-only and are not a production path.
Readings still hit a durable log on the box. Camera clips stay in local evidence storage. Local analytics and alerts keep running. When the link returns, store-and-forward sends the backlog to TwinEdge Historian and the cloud.
Not unless a person lets it. Proposed actions wait in an approval queue. BACnet writes go through a commissioning path with readback, not the ingest loop. Safety envelopes and kill switches stay on. Fire and suppression points are never writable.
No. Facility OS uses TwinEdge AssetOps for work orders, or sits beside the CMMS you already run. The finding and the job share the building record.
Discuss your sources, assets, and the outcomes your team wants to improve.