Electric submersible pump

You cannot see an ESP. Intake pressure, motor temperature and current tell you how it is doing.

An ESP sits thousands of feet down, out of reach until a rig pulls it. Its pump curve, the inflow from the reservoir and the cooling of its motor all follow equations we can write down. The twin puts the gauge and drive readings on those curves and says when the pump is drifting out of its range.

150 hp ESP, 2,000 bbl/d at 60 Hz, 200 stages, set at 6,800 ft

Built and run to API RP 11S, API RP 11S4

Sketch of an electric submersible pump installation: variable speed drive, step-up transformer and junction box at surface, wellhead and flowline, power cable down the tubing to the downhole string of pump stages, intake and gas separator, seal section, motor and downhole gauge above the perforations, with numbered sensor points.123456drivetransformerto separatorpump, 200 stagesintake and gas separatorsealmotordownhole gaugeperforations6,800 ftpower cable
Flow
2,001 bbl/d
Head
5,138 ft
Motor load
79%
Intake pressure
938 psi

Anatomy and nameplate

Sketch of an electric submersible pump installation: variable speed drive, step-up transformer and junction box at surface, wellhead and flowline, power cable down the tubing to the downhole string of pump stages, intake and gas separator, seal section, motor and downhole gauge above the perforations, with numbered sensor points.123456drivetransformerto separatorpump, 200 stagesintake and gas separatorsealmotordownhole gaugeperforations6,800 ftpower cable
  1. 1Intake pressure. Fluid over the pump. With the inflow curve, it gives flowing bottomhole pressure.
  2. 2Motor temperature. Winding temperature from the downhole gauge. Cooled only by the fluid going past.
  3. 3Drive frequency and current. Speed sets the pump curve. Current shows load, gas and underload.
  4. 4Discharge pressure. With intake pressure, gives the head the pump is making.
  5. 5Wellhead pressure. Back pressure from the flowline.
  6. 6Wellhead temperature. Fluid temperature at surface. Falls when flow falls.
Electric submersible pump nameplate
Pump
TypeCentrifugal, 200 stages, mixed flow
Design flow (BEP)2,000 bbl/d at 60 Hz
Head at BEP5,140 ft (25.7 ft per stage)
Shutoff head6,939 ft
Efficiency at BEP62%
Recommended range75% to 125% of BEP (1,500 to 2,500 bbl/d at 60 Hz)
IntakeRotary gas separator
Motor and drive
Motor150 hp, 2,300 V, 40 A, 5.4 in OD
DriveVariable speed drive with step-up transformer
Load at design118 hp, 79% of nameplate, 32.7 A
Downhole gaugeIntake pressure, motor temperature, discharge pressure
Motor temperature limit177 °C
Well
Setting depth6,800 ft, perforations at 7,000 ft
Casing7 in, 6.276 in ID
Reservoir pressure2,400 psi, Vogel q_max 2,600 bbl/d
Operating point2,001 bbl/d at 5,138 ft, intake 938 psi
Fluid80% water cut, 0.42 psi/ft
Flow past the motor2.3 ft/s at design, 1 ft/s at 858 bbl/d

From the well to market

Wells lift the fluid. The separator splits it. Oil goes to the tank battery and gas to the compressor station, and both leave by pipeline for processing.

Well on rod pump: Beam pumping unitWell on rodpumpBeam pumpWell on ESP: Electric submersible pumpWell on ESPSubmersible pumpSeparator: Splits oil, gas and waterSeparatorOil, gas, waterTank battery: Crude storage tanksTank batteryCrude storageCompressor station: Reciprocating gas compressorsCompressorstationGas compressorsPipeline: Oil and gas to marketPipelineTo marketProcessing: Crude preheat exchangersProcessingCrude preheat
  • Well fluid
  • Crude oil
  • Gas
  • Has its own twin page

The physics

The equations behind every curve on this page.

Affinity laws

Q ∝ f H ∝ f² P ∝ f³

The drive moves the whole pump curve. Ten percent less speed is 19% less head.

Inflow (Vogel)

q/q_max = 1 − 0.2·(Pwf/Pr) − 0.8·(Pwf/Pr)²

How much the reservoir gives for each step down in bottomhole pressure.

Head the well asks for

TDH = (P_wh + g·D + ΔP_f − PIP) / g

Lift to surface plus friction and back pressure, less what the fluid over the pump already pushes.

Motor cooling

ΔT ∝ losses / h h ∝ v^0.8

Fluid past the motor carries the heat away. 2.3 ft/s at design.

Where the pump runs

The pump curve, the drive frequency and the reservoir decide the flow together. The point moves as the reservoir drops.

Operating point on the pump curve

200 stages. Shaded band is the recommended range at 60 Hz.

Operating point on the pump curveRecommended range02,0004,0006,0008,00005001,0001,5002,0002,5003,0003,5002,001 bbl/d today1,429 bbl/d, 71% of BEPFlow (bbl/d)Head (ft)
  • 60 Hz
  • 50 Hz
  • 66 Hz
  • Well today, 2,400 psi
  • Well a year on, 1,900 psi
Today
2,001 bbl/d at 5,138 ft, 118 hp
A year on
1,429 bbl/d, below range

The pump makes the head on its curve. The well asks for the head on its own curve. Where they cross is where it runs. As the reservoir drops, that point slides left, out of the range, and the stages start to ride on their downthrust washers.

Q ∝ f, H ∝ f², P ∝ f³ q/q_max = 1 − 0.2·(Pwf/Pr) − 0.8·(Pwf/Pr)²

Gas and heat

Gas and low flow are the two things that kill ESPs early. Each leaves its own pattern in the gauge and the drive.

Intake pressure and current through a gas slug

60 Hz, no change at the drive

Intake pressure and current through a gas slugGas locked8509009501,0001,0501,1001,150010203040500102030405060708090Underload 26 AMinutesPump intake pressure (psi)Motor current (A)
  • Intake pressure
  • Motor current (right axis)
Current, normal
32.7 A
Current, low point
16.6 A
Intake pressure, peak
1,105 psi

Gas cuts the head the stages can make. Flow stops, current falls toward no-load, and liquid builds up over the pump. Current alone looks like an underload trip. Current falling while intake pressure climbs says gas.

dPIP/dt = g · (q_in − q_pump) / A_annulus

Motor temperature against flow past the motor

Design load 118 hp, well at 95 °C, 5.4 in motor in 6.276 in casing

Motor temperature against flow past the motor1001201401601802002202402605001,0001,5002,0002,5003,000Motor limit 177 °C1 ft/s at 858 bbl/d125 °C at 2,001 bbl/dFlow past the motor (bbl/d)Motor winding temperature (°C)
  • Winding temperature

The only thing cooling the motor is the well fluid flowing past it. Cut the flow and the winding heats up fast, long before the current looks wrong.

ΔT ∝ motor losses / h h ∝ v^0.8 v = Q / A_annulus

Failure modes

What breaks, what it looks like, what the twin does about it.

Failure modeThe physicsSignals that show itHow the twin catches it
Gas lockFree gas fills the stages, which cannot make head with gas, so flow stops.Current falls toward no-load. Intake pressure climbs. Wellhead temperature drops.Reads current and intake pressure together, so gas is not mistaken for an underload or a broken shaft.
Running outside the recommended rangeBelow the range the stages ride down on their thrust washers. Above it they ride up.Operating point left or right of the range on the curve. Vibration where the gauge has it.Places each reading on the curve at the drive frequency and flags time below 75% or above 125% of BEP.
Scale or solidsDeposits narrow the stage passages, so each stage makes less head.Discharge minus intake pressure falls at the same flow and frequency. Current creeps up.Compares head made with the curve and trends the loss stage by stage.
Motor insulation breakdownHeat and well fluid wear down the winding insulation.Motor temperature high for the load. Phase imbalance and insulation resistance at the drive.Works out the expected winding temperature from load and flow, and adds up the hours spent hot.
Cable faultsGas and pressure cycling break down the cable insulation along the tubing.Phase current imbalance. Ground fault readings at the drive.Trends imbalance and leakage from the drive against the motor load.

What the twin does not do

  • The drive keeps its own protection. Underload, overload and ground fault trips stay with it. TwinEdge is never in the safety loop.
  • We suggest frequency changes. Your people make them at the drive or through SCADA.

How we catch it early

A physics twin and a PINN, working on one electric submersible pump.

The twin is a set of equations for this machine, tuned to its nameplate. Give it the flow, speed and conditions and it returns what every reading should be. It always gives the same answer for the same inputs.

A physics-informed neural network, or PINN, sits on top. It is trained on the plant’s own data and it is penalized whenever it breaks a physics rule. So it can only learn what the equations leave out: wear, fouling, friction. It cannot invent an answer that the machine could never produce.

  1. Step 1

    Measure

    Flow, pressure, current, temperature, vibration. Whatever the asset already has.

  2. Step 2

    Physics twin

    The equations of this machine, set to its nameplate. It says what the readings should be right now.

  3. Step 3

    Residual

    Measured minus expected. Demand, weather and speed are already taken out.

  4. Step 4

    PINN

    A small neural network that learns the cause of the gap, under the physics rules.

  5. Step 5

    Finding

    A named cause, a date, and the kWh or hours at stake. An engineer reviews it.

loss = (measured − predicted)² + λ · (physics residual)²

The second term is the rulebook. It is zero when the network obeys the equations.

Why this beats black-box AI

A black-box model learns patterns from history. It needs examples of each failure, and it goes quiet when the pump runs at a point it has not seen. The twin starts from physics, so it works on day one. The PINN adds what physics cannot know about this particular machine.

That is also what makes the savings countable. The baseline is a calculation, not a guess, so the gap between baseline and meter is a number a customer can check.

What the twin checks on this asset

  • Operating point on the pump curve at the drive frequency
  • Intake pressure against the inflow curve
  • Motor temperature against load and flow past the motor
  • Current and intake pressure read together for gas
Fixed alarmBlack-box AITwin + PINN
Needs failure history to learnNoYes, lotsNo
Says what is wrongNoRarelyYes, by name
Works at a flow it has never seenNoOften failsYes, the equations still hold
Puts a number on the savingNoNoYes, in kWh and dollars
Lead time on slow wearLateVariesWeeks to months
Every number can be tracedYesNoYes, to an equation

What the twin puts a number on

Energy and cost, from the equations.

Design point

2,001 bbl/d

5,138 ft at 118 hp, 100% of BEP

A year on, at 60 Hz

71% of BEP

1,429 bbl/d with the reservoir at 1,900 psi. Below the range.

Each day the well is down

400 bbl oil

$28,015 at $70 per bbl

Motor at 900 bbl/d

150 °C

Against 125 °C at design flow, same load

What we do for you

We watch it. We catch it. We prove it.

Our reliability engineers run the twin on your electric submersible pump, review every finding, and help your crew fix it. After the repair we compare the meter to the baseline and write the result in the ledger.