Home/Commercial Facilities/HVAC Optimization

Commercial Facilities

HVAC Optimization

Optimize heating, ventilation, and cooling systems with physics-based digital twins. Reduce energy consumption 15-25% while improving occupant comfort.

BUILDING CROSS-SECTIONAHU-01AIR HANDLING UNITOUTSIDE AIR85.0°FOATSUPPLYRETURNFLOOR 3ZONE TEMP72.0°FSP: 72°FDAMPER: 45%VAV300 CFMFLOOR 2ZONE TEMP73.5°FSP: 71°FDAMPER: 68%VAV384 CFMFLOOR 1ZONE TEMP73.4°FSP: 73°FDAMPER: 26%VAV391 CFMWATER LOOPSCHILLED WATERSupply: 44°FReturn: 56°FHOT WATERSupply: 180°FReturn: 160°FFILTER STATUSdP: 0.80 inWCENERGY METER247.3kWhCOMFORT INDEX75%PMV: 0.20PPD: 5.0%MARGINALASHRAE 55 CompliantHVAC SYSTEM STATUSAHU-01RUNNINGChillerSTAGE 2BoilerSTANDBYEconomizerMIXEDOAT Delta+13.0°Fvs avg setpoint

HVAC Asset Coverage

From rooftop units to terminal boxes, every component modeled.

AssetMonitoringDigital Twin
Air Handling UnitsSAT, RAT, MAT, filter dP, fan speed, damper positionMixed-air model, economizer optimization, coil performance
Rooftop UnitsCompressor amps, condenser pressure, EAT/LAT, defrostCOP degradation trending, refrigerant charge model
VAV BoxesAirflow CFM, zone temp, damper position, reheat valveZone comfort scoring, simultaneous heating/cooling detection
Exhaust FansMotor current, vibration, static pressure, runtimeBearing degradation, belt slip detection, flow verification
Heat PumpsEntering/leaving water temp, compressor power, flow rateCOP calculation, source-side capacity tracking, defrost efficiency

Optimization Capabilities

Comfort, efficiency, and reliability in a single platform.

Zone Comfort Tracking

Real-time PMV/PPD comfort scoring for every zone. Identify hot/cold complaints before occupants call. Track comfort SLA compliance.

Setpoint Optimization

AI-driven supply air and static pressure reset based on zone demand. Reduce fan energy 20-30% without comfort sacrifice.

Fault Detection & Diagnostics

ASHRAE RP-1312 fault rules applied continuously. Detect stuck dampers, leaking valves, sensor drift, and simultaneous heating/cooling.

Energy Benchmarking

Compare kBtu/sqft across buildings, floors, and zones. Benchmark against ASHRAE 90.1 baselines and track improvement over time.

Economizer Optimization

Maximize free cooling hours with dry-bulb and enthalpy switchover optimization. Detect failed economizer modes costing thousands annually.

Demand-Based Ventilation

CO2-based ventilation control with per-zone OA tracking. Meet ASHRAE 62.1 requirements while minimizing outside air conditioning load.

15-25%
Energy Reduction
Typical first-year savings from setpoint optimization and FDD
40%
Fewer Comfort Calls
Proactive zone management reduces occupant complaints
3.2x
Equipment Life Extension
Condition-based maintenance replaces calendar-based PM

Start Saving on HVAC Energy

See how TwinEdge delivers measurable HVAC savings with automated fault detection and optimization.